Basic Info
  • Model NO.:spc polyurea

  • Type:Roofing and Waterproofing

  • Ceiling Tile Shape:Roll

  • Material:Polyurea

  • Waterproofing Coating Thickness:2.0mm

  • Ceiling Tile Type:Polyurea

  • Surface Treatment:Roll Coated

  • Function:Waterproof

  • Certification:ISO, CE

  • Waterproofing Coating Color:White

  • Usage:Outdoor

  • Product Name:Polyurea Coating

  • Raw Material:Polyurethane Waterproof Coating

  • Solid Content:100%

  • Waterproofing Coating Proportion:Two Components, 1:1 Mix

  • Method:Spray

  • Dosage:0.7-2.5kg/Sqm

  • Density:1.01±0.1g/Cm3

  • Transport Package:200kg/Barrel

  • Specification:CE, SGS

  • Origin:Shanghai

  • HS Code:29291030

Two Components Polyurea Waterproofing Spray Coatings for Railway Product Description

 Polyurea waterproofing has been widely used and tunnel, swimming pool, Bridges, roof leak proof, etc., polyurea excellent waterproof performance, has gradually replaced traditional waterproof material,
Features of polyurea coatings:
1. The solid content of 100%, no volatile, non-toxic, conform to the requirements of environmental protection
2. The excellent physical properties such as strength, hardness, toughness, hardness is adjustable
3. The compact coating, anticorrosive, waterproof, wear-resisting performance is remarkable
4. Strong weatherability, outdoor use for a long time not crack, not pulverization, not an omission
5. In steel, aluminum, concrete, wood, plastic and other kinds of all have good adhesion on 
6. Good thermal stability, can be long-term use under 150 oC, can withstand the temperature of 250 oC
7. To join various pigments, fillers, made into different colors of different characteristics of products
8. Is not sensitive to humidity and temperature, the construction strong adaptability to environment
9. Fast curing, construction not sag;Can a construction requirements, short construction period
After construction is easy to repair the jointless, beautiful and practical

Specification of polyurea coatings:

Item

 TypeI

 Type II

Solid content (%)

99

99

Gel time (s)

20

20

Table dry time (s)

40

40

Tensile strength (MPa)

18

23

Break elongation (%)

375

510

Tear strength (N/mm)

66

77

Adhesion (MPa)

3.6

4.2

Low temperature bending (oC)

-35

-40

Water impermeability (0.4MPa, 2h)

impervious

impervious

Heating expansion rate (%)

≤1.0

0.4

water absorption rate (%)

2.5

2.5

Hardness (shore A)

85~95

85~95

Wear resistance [(750g/750r)/mg]

13

13

Impact resistance (kg.m)

1.0

1.0

Artificial climate aging (2000h)

good

good

Density (g/cm3)

1.02

1.02

Color

can be modulated according to requirement

 
Note: Due to the difference of field conditions, the actual measured data may differ from the above data.
 
Theoretical amount of polyurea coatings:
 
Recommended film thickness is about 1.5-2.5mm, estimated consumer consumption amount for 2.0-3.0kg/square meters, the amount of nodes, corners and some special parts may than theoretical consumption greater.
 
The shortest, time is not limited;
 
The longest, no more than 3 hours
Commonly used SBS,APP roofing waterproof material such as the following problems:
1. Have juncture, easy appear juncture place not firm and water penetration
2. Due to the low strength of materials, substrate crack and fracture, cause leakage
3. Long after the rain and snow and wind and frost's exposure to the sun's ultraviolet rays, material aging crack leakage



Two Components Polyurea Waterproofing Spray Coatings for Railway Applications
 Suitable for: all kinds of building roof waterproof leakproof and bridge, reservoirs, tunnel and underground engineering and power plant cooling tower, water tank, aquarium, swimming pool, etc. Lining concrete structure
Not only widely used in ordinary engineering waterproof construction, but also can be used for difficult waterproof engineering, such as municipal construction of underground waterproofing, the tunnel seepage control and all kinds of corrosive sewage treatment area of ditch, the pool of waterproof anti-corrosion engineering construction.

 
Two Components Polyurea Waterproofing Spray Coatings for Railway Packaging & Shipping
 
  Material A is 220kg per red iron drum, material B is 220kg per blue iron drum. 
 
Storage and transportation of polyurea coatings:
 
This product should be stored in cool, ventilated, dry coffers in the presence, is strictly prohibited in the rain, sun, cut off from the source of the fire. Keep away from heat and storage temperature should be 10 to 40oC.
 
This product if not open the original packaging, the storage period is 6 months since the date of production. If over storage period could be tested according to the product standards for inspection, if meet technical requirements can still be used.
 
 

This product does not contain organic solvents, can be transported by non dangerous goods. Transport should be no rain, the sun, and should comply with the relevant provisions of the Department of transportation.


Two Components Polyurea Waterproofing Spray Coatings for Railway